Created on 06/17/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
FPHK
Pilot operated, normally closed, electro-proportional throttle with reverse flow
check
SERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-16A
X-Control, C-Spool
E-Control, C-Spool
M-Control, C-Spool
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing
the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally.
Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
TECHNICAL DATA
Recommended dither frequency 100 Hz
Maximum Valve Leakage at 110 SUS (24 cSt) 0,7 cc/min.@350 bar
Manual Override Force Requirement 33 N/100 bar @ Port 1
Deadband, nominal (as a percentage of input) 25%
Manual Override Stroke 1,50 mm
Seal kit - Cartridge Buna: 990-016-007
Seal kit - Cartridge Polyurethane: 990-016-002
Seal kit - Cartridge Viton: 990-016-006
(X)CONTROL
X No Manual Override
E Twist (Extended) Manual Override
M Manual Override
(C)FLOW RATE
C Nominal 40 gpm @ 200 psi ( 14 bar)
differential (160 L/min.)
A Nominal 20 gpm @ 200 psi ( 14 bar)
differential (80 L/min.)
E Nominal 60 gpm @ 200 psi ( 14 bar)
differential (240 L/min.)
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
COIL *
No coil
212DIN 43650 3 pin (Hirschman), 12 VDC
224DIN 43650 3 pin (Hirschman), 24 VDC
712Twin Lead, 12 VDC
724Twin Lead, 24 VDC
912Deutsch DT04-2P, 12 VDC
924Deutsch DT04-2P, 24 VDC
* Additional coil options are available
snhy.com/
FPHK
TECHNICAL FEATURES
Capable of operating with pressures up to 5000 psi.
Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
This cartridge has several manual override choices, including no manual override. See Option Configuration.
For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Model Code Example: FPHKXCNCONFIGURATION OPTIONS
Created on 06/17/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
RELATED ACCESSORIES
991-238 Momentary/twist operation, extended resolution, manual override control kit, E control
991-240 Red momentary/twist operation, manual override control kit, T control
991-241 Red detent/lock operation, manual override control kit, L control
991-242 Red dual twist/lock operation, manual override control kit, D control
991-243 Red momentary/twist operation, extended resolution, manual override control kit, E control